Corrosion Behaviour of Metals in Artificial Tear Solution

Authors

  • C. Kumar Periyar E.V.R. College (Autonomous), Trichy-620023, Tamil Nadu
  • A. John Amal Raj Periyar E.V.R. College (Autonomous), Trichy-620023, Tamil Nadu
  • S.K. Selvaraj GTN Arts College, Dindigul-624005, Tamil Nadu

DOI:

https://doi.org/10.24297/jac.v8i3.4051

Keywords:

Corrosion of metals, artificial tear, Ni-Cr, SS 316 L

Abstract

Human tear comes in contact with a number of instruments during operation in the eyes.  This results in a variety of undesirable effects such as corrosion and malfunction.  Corrosion behaviour of five metals, namely, mild steel (MS), mild steel coated with zinc (MS-Zn), Ni-Cr, Ni-Ti super elastic (Ni-Ti.SE), and SS 316 L in artificial tear solution has been studied by polarization study and AC impedance spectra.  The study reveals that the decreasing order of corrosion resistance in artificial tear solution is : Ni-Ti SE > Ni-Cr > SS 316 L > MS-Zn > MS.  The first three metals are better candidates and the first one is the best candidate for making instruments used in operation in the eyes, in presence of tears.

Downloads

Download data is not yet available.

Author Biographies

  • C. Kumar, Periyar E.V.R. College (Autonomous), Trichy-620023, Tamil Nadu
    PG and Research Department of Chemistry
  • A. John Amal Raj, Periyar E.V.R. College (Autonomous), Trichy-620023, Tamil Nadu
    PG and Research Department of Chemistry
  • S.K. Selvaraj, GTN Arts College, Dindigul-624005, Tamil Nadu
    Corrosion Research Centre, PG and Research Department of Chemistry

Downloads

Published

2016-12-21

Issue

Section

Articles

How to Cite

Corrosion Behaviour of Metals in Artificial Tear Solution. (2016). JOURNAL OF ADVANCES IN CHEMISTRY, 8(3), 1716-1735. https://doi.org/10.24297/jac.v8i3.4051